Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 18(8): 6612-6622, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38359901

RESUMO

To perform multiplex profiling of single cells and eliminate the risk of potential sample loss caused by centrifugation, we developed a microfluidic flow cytometry and mass spectrometry system (µCytoMS) to evaluate the drug uptake and induced protein expression at the single cell level. It involves a microfluidic chip for the alignment and purification of single cells followed by detection with laser-induced fluorescence (LIF) and inductively coupled plasma mass spectrometry (ICP-MS). Biofunctionalized nanoprobes (BioNPs), conjugating ∼3000 6-FAM-Sgc8 aptamers on a single gold nanoparticle (AuNP) (Kd = 0.23 nM), were engineered to selectively bind with protein tyrosine kinase 7 (PTK7) on target cells. PTK7 expression induced by oxaliplatin (OXA) uptake was assayed with LIF, while ICP-MS measurement of 195Pt revealed OXA uptake of the drug in individual cells, which provided further in-depth information about the drug in relation to PTK7 expression. At an ultralow flow of ∼0.043 dyn/cm2 (20 µL/min), the chip facilitates the extremely fast focusing of BioNPs labeled single cells without the need for centrifugal purification. It ensures multiplex profiling of single cells at a throughput speed of 500 cells/min as compared to 40 cells/min in previous studies. Using a machine learning algorithm to initially profile drug uptake and marker expression in tumor cell lines, µCytoMS was able to perform in situ profiling of the PTK7 response to the OXA at single-cell resolution for tests done on clinical samples from 10 breast cancer patients. It offers great potential for multiplex single-cell phenotypic analysis and clinical diagnosis.


Assuntos
Nanopartículas Metálicas , Microfluídica , Humanos , Citometria de Fluxo , Ouro , Biomarcadores , Espectrometria de Massas/métodos , Moléculas de Adesão Celular , Receptores Proteína Tirosina Quinases
2.
Anal Chem ; 95(44): 16176-16184, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37879040

RESUMO

The exploration of cytology mechanisms of nanosilver uptake, toxicity, and detoxification has become an important issue due to its widespread applications. Previous studies have shown differences in the toxic response of mammalian cells to nanosilver. However, the analysis results based on cell populations ignore the impact of cell uptake heterogeneity on the expression of associated stress proteins and cellular physiological activities. In this respect, this work investigated the interaction between silver uptake and metallothionein (MT) expression in individual cells. In addition, we have also preliminarily elucidated the sensitivity variation to AgNPs by using five cell lines, e.g., LX-2, HepG-2, SK-HEP-1, Huh-7, and MDA-MB-231, by adopting a two-dimensional (2D) high-throughput single-cell analysis platform coupling laser-induced fluorescence (LIF) and inductively coupled plasma mass spectrometry (ICP-MS). We developed a 2D data analysis method for one-to-one unification of fluorescence-mass spectrometry signals corresponding to a specific single cell. It indicated that there is no obvious correlation between cellular silver uptake and cell size, and the low MT expression of cells is more sensitive to silver nanoparticles. For each cell line, significant heterogeneity in MT expression was observed. This provides important information for understanding the potential heterogeneous effects of nanosilver on mammalian biological systems. Overall, detoxified cells are more tolerant to nanosilver and normal cells are more tolerant than cancer cells.


Assuntos
Nanopartículas Metálicas , Prata , Animais , Prata/química , Metalotioneína/química , Mamíferos/metabolismo , Análise de Célula Única
3.
Lab Chip ; 22(21): 4238-4245, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36194170

RESUMO

In aptamer-based assay schemes, aptamer probes not labeled with biomarkers have to be eliminated before testing, which may lead to a tremendous waste of precious probes. We herein propose a microfluidics system integrating an aptamer concentration gradient generator (Apt-CGG) and a dual single-cell culturing array (D-SCA), termed Mi-Apt-SCA. This facilitates the precise construction of a nanoscale-gradient microenvironment and the high-throughput profiling of single-cell growth/phenotypes in situ with the minimal consumption of Apt-probe. Unlike previous snakelike mixers, the choreographed winding-ravined aptamer dual-spiral micromixer (Apt-WD-mixer) in Apt-CGG could allow thorough blending to generate linear concentration gradients of aptamer (quasi-non-Newtonian fluid) under the action of continuous fluidic wiggles and bidirectional Dean flow. In contrast to other trap-like systems, the mild vortex allows single-cell growth in an ultra-tender fluidic microenvironment using triple-jarless single-cell culture capsules (TriJ-SCCs) in D-SCA (shear stress: 3.43 × 10-5 dynes per cm2). The minimum dosage of aptamer probe required for exploring PDL1 protein expression in two hepatoma cell lines is only one-900th of that required by conventional protocols. In addition, this approach facilitated the profiling of ITF-ß/cisplatin-mediated single-cell/cell-cluster phenotypes.


Assuntos
Aptâmeros de Nucleotídeos , Produtos Biológicos , Neoplasias Hepáticas , Humanos , Aptâmeros de Nucleotídeos/metabolismo , Cisplatino , Microambiente Tumoral
4.
Anal Chim Acta ; 1226: 340268, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36068064

RESUMO

The cellular metabolism of metals is highly critical to elucidate their potential cytotoxicity or cell protection mechanism. In this work, an asymmetric serpentine microfluidic device (ASMD) with high sampling efficiency and excellent focusing performance was developed for single-cell focusing. ASMD coupling with ICP-MS ensures single-cell assay to provide the information for trivalent arsenic (As(III)) uptake by HepG2 cells, which reveals the heterogeneity of cellular arsenic distribution, and elucidates the arsenic elimination behaviors in single HepG2 cells. Further, the metabolism and transformation of As(III) in HepG2 cells was tracked by hyphenating capillary electrophoresis (CE) separation with ICP-MS. The results for single-cell analysis and arsenic elimination kinetics illustrated that the half-life of arsenic elimination is 0.9 ± 0.04 h with the elimination constant of 0.77 ± 0.03, i.e., 77% of accumulated As in HepG2 cells may be eliminated per hour. Moreover, arsenobetaine (AsB) was identified to be the main metabolite and biotransformation species of As in HepG2 cells. ASMD-ICP-MS and CE-ICP-MS are powerful for tracking the fate of metals or metal drugs in single cells to comprehensively understand their metabolic pathway and transformation behaviors.


Assuntos
Arsênio , Arsênio/análise , Arsênio/toxicidade , Eletroforese Capilar/métodos , Células Hep G2 , Humanos , Espectrometria de Massas/métodos , Análise Espectral
5.
Anal Chem ; 94(23): 8547-8553, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35653437

RESUMO

Laser ablation inductively coupled plasma mass spectrometry imaging of biologically significant targets largely relies on maintaining the original structures of samples. The temperature regulation capability of the ablation cell is crucial. Herein, a rapid cooling cryogenic sample cell (RCCSC) was developed. In the RCCSC chamber, the temperature reduces to -20 °C in 4 min with a minimum 10 h variation of ±0.1 °C at -26 °C. Improvements on the precision were achieved for the elements of interest in NIST 612 and spiked agarose gel under cryogenic conditions. The limits of detection improved by up to 1.57, 1.70, 3.26, and 1.33 fold for 63Cu, 66Zn, 57Fe, and 140Ce in agarose gel, respectively, were obtained under cryogenic conditions compared with those at room temperature. In a time period of testing (10 h), the cryogenic ablation maintains the native state of biological tissues with a high water content to ensure better elemental imaging by reducing thermal effects in ablation and suppressing evaporation of water. The rapid cooling cryogenic ablation significantly improves elemental imaging, as demonstrated by the imaging of various elements in coriander leaves. The present study may provide further insights into elemental distributions in fresh biological samples.


Assuntos
Terapia a Laser , Diagnóstico por Imagem , Espectrometria de Massas/métodos , Sefarose , Água
6.
ACS Omega ; 7(2): 1628-1638, 2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35071858

RESUMO

Introduction: Smoking affects the occurrence and development of many diseases. We attempt to study the structure of intestinal flora in the middle-aged and elderly population as well as how smoking affects the intestinal flora. Methods: We collected population information, biochemical indicators, and patient feces from 188 middle-aged and elderly male patients, and their feces were tested for the 16S rRNA gene of intestinal flora. Results: We performed a cluster analysis on the intestinal structure of the included population and found that there was a significant difference in the number of smokers between each group (p = 0.011). Subsequently, the microbiological diversity analysis of current smokers and nonsmokers was carried out. The results indicated that there was a significant difference in species composition between the two groups (p = 0.029). Through the analysis on LEfSe differential bacteria, it was found that in current smoking patients, the abundances of the genus Bifidobacterium and the genus Coprobacillus were less, while the abundances of the genera Shigella, Paraprevotella, Burkholderia, Sutterella, Megamonas, and p-75-a5 under the family level of Erysipelotrichaceae were slightly high. We analyzed the correlation between the abundances of these eight different bacteria and clinical indicators. The results revealed the following: the abundance of the genus Bifidobacterium was negatively correlated with fasting blood glucose (r = -0.198, p = 0.006) and positively correlated with uric acid (r = 0.207, p = 0.004) and total bilirubin (r = 0.175, p = 0.017); Shigella bacteria were positively correlated with fasting blood glucose (r = 0.160, p = 0.028) and uric acid (r = 0.153, p = 0.036) levels; the genus Paraprevotella and BMI (r = -0.172, p = 0.018) are negatively correlated; the abundance of the genus Burkholderia was positively correlated with γ-glutamyltransferase (r = 0.146, p = 0.045) levels; Sutterella was correlated with fasting blood glucose (r = 0.143, p = 0.05) and creatinine level (r = -0.16, p = 0.027), which was positively correlated with fasting blood glucose and negatively correlated with creatinine. Conclusions: In middle-aged and elderly patients with cardiovascular disease, smoking can reduce the abundance of Bifidobacterium, while the abundances of some negative bacteria such as Burkholderia, Sutterella, and Megamonas increase.

7.
ACS Appl Mater Interfaces ; 13(36): 43668-43675, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34473482

RESUMO

The efficient recognition of circulating tumor cells (CTCs) with an aptamer probe confers numerous benefits; however, the stability and binding affinity of aptamers are significantly hampered in real biological sample matrices. Inspired by the efficient preying mechanism by multiplex tubing feet and endoskeletons of sea urchins, we engineered a superefficient biomimetic single-CTC recognition platform by conjugating dual-multivalent-aptamers (DMAs) Sgc8 and SYL3C onto AuNPs to form a sea urchin-like nanoprobe (sea urchin-DMA-AuNPs). Aptamers Sgc8 and SYL3C selectively bind with the biomarker proteins PTK7 and EpCAM expressed on the surface of CTCs. CTCs were captured with 100% efficiency, followed by sorting on a specially designed multifunctional microfluidic configuration, integrating a single-CTC separation unit and a hydrodynamic filtrating purification unit. After sorting, background-free analysis of biomarker proteins in single CTCs was undertaken with inductively coupled plasma mass spectrometry by measuring the amount of 197Au isotope in sea urchin-DMA-AuNPs. With respect to a single-aptamer nanoprobe/-interface, the dual-aptamer nanoprobe improves the binding efficiency by more than 200% (Kd < 0.35 nM). The microchip facilitates the recognition of single CTCs with a sorting separation rate of 93.6% at a flow rate of 60 µL min-1, and it exhibits 73.8 ± 5.0% measurement efficiency for single CTCs. The present strategy ensures the manipulation and detection of a single CTC in 100 µL of whole blood within 1 h.


Assuntos
Aptâmeros de Nucleotídeos/química , Separação Celular/métodos , Ácidos Nucleicos Imobilizados/química , Dispositivos Lab-On-A-Chip , Nanopartículas Metálicas/química , Células Neoplásicas Circulantes/química , Materiais Biomiméticos/química , Moléculas de Adesão Celular/química , Linhagem Celular Tumoral , Molécula de Adesão da Célula Epitelial/química , Ouro/química , Humanos , Espectrometria de Massas , Técnicas Analíticas Microfluídicas/métodos , Receptores Proteína Tirosina Quinases/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...